Secured Trading Service

Air handling unit (AHU) for pharmaceutical temperature and humidity control

  • Audited Supplier
  • 2 yrs
  • leading factory

Contact Supplier

Product Highlights

  • 2-Year Comprehensive Warranty: Covers mechanical defects with free parts and labor for 2 years.
  • 7/24 Quick Service Response: Online and on-site support available around the clock for maintenance.
  • Free Spare Parts Included: Each order comes with complimentary spare parts for rapid service.
  • Long Lifespan Over 20 Years: Durable design ensures reliable operation for more than two decades.
  • Multiple Heating Options: Supports Gas, Steam, and Electricity heating configurations.
  • Customizable Wall Panel Thickness: Wall panel thickness can be customized to 50mm per requirements.
  • Premium Wooden Case Packaging: Sections packed in shrink film and secured in wooden cases.
  • RoHS, ISO, CE Certified: Meets international safety and quality standards for pharmaceutical use.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Air handling unit (AHU) for pharmaceutical temperature and humidity control

Air handling unit (AHU) for pharmaceutical temperature and humidity control
Air handling unit (AHU) for pharmaceutical temperature and humidity control pictures & photos
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Air handling unit (AHU) for pharmaceutical temperature and humidity control pictures & photos
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Air handling unit (AHU) for pharmaceutical temperature and humidity control pictures & photos
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Air handling unit (AHU) for pharmaceutical temperature and humidity control pictures & photos
Air handling unit (AHU) for pharmaceutical temperature and humidity control
  • Air handling unit (AHU) for pharmaceutical temperature and humidity control
  • Air handling unit (AHU) for pharmaceutical temperature and humidity control
    Air handling unit (AHU) for pharmaceutical temperature and humidity control
  • Air handling unit (AHU) for pharmaceutical temperature and humidity control
    Air handling unit (AHU) for pharmaceutical temperature and humidity control
  • Air handling unit (AHU) for pharmaceutical temperature and humidity control
    Air handling unit (AHU) for pharmaceutical temperature and humidity control
  • Air handling unit (AHU) for pharmaceutical temperature and humidity control
    Air handling unit (AHU) for pharmaceutical temperature and humidity control

Find Similar Products

Product Description

Product Description
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Air Handling Unit (AHU) isused to regulate and circulate air as part of a heating, ventilation, and air conditioning (HVAC) system. It conditions and distributes air throughout a building while maintaining indoor air quality (IAQ), temperature, and humidity levels. AHUs are essential for maintaining comfort, safety, and efficiency in environments where air quality and climate control are critical.
Key functions of an AHU:
* Air Intake & Filtration – Draws in fresh outdoor air and filters out dust, pollutants, and contaminants.
* Temperature Control – Heats or cools the air using coils (hot water, chilled water, or refrigerant).
* Humidity Regulation – Adjusts moisture levels via humidifiers or dehumidifiers.
* Air Distribution – Uses fans and ductwork to supply conditioned air to different zones.
* Ventilation & Exhaust – Removes stale air and ensures proper air exchange for a healthy environment.
* Energy Recovery – Some AHUs include heat exchangers to improve energy efficiency by reusing waste heat.

Industries where AHUs are applied:
* Commercial Buildings (Offices, shopping malls, hotels)
* Healthcare Facilities (Hospitals, laboratories – requiring sterile airflow)
* Pharmaceutical & Cleanrooms (Precise air quality control)
* Manufacturing & Industrial Plants (Dust control, temperature regulation)
* Data Centers (Cooling for sensitive IT equipment)
* Educational Institutions (Schools, universities)
* Food & Beverage Industry (Hygienic air handling for production areas)
* Residential (Large-scale HVAC systems in apartments/high-rises)
Specification
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Certifications
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Packing & Delivery
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Standard packaging
Premium pakaging
Each section of dehumidifer is packed with shrink film.
Each section of dehumidifer is packed into wooden case.
After Sales Service
Training and on-site commissiong available
•Providing customers with online or on-site installation and maintenance training.
•Monitoring and tracking status of equipment operation performance.
•Each order attached with free of charge spare parts for customer quick service.
•7/24 quick service responsiveness.
Company Profile
Air handling unit (AHU) for pharmaceutical temperature and humidity control
Jiangsu Sujing Group Co., Ltd
Dedicated to overall solutions for equipment manufacturing in the field of dehumidification and environmental protection. styles to meet your needs.
• History: Established in 1970, state-owned high-tech company
• Size: 130,000 square meters
• Employees: 1000+
FAQ
1. Why is regular AHU maintenance important?
2. How often should an AHU be serviced?
3. What are the signs that an AHU needs maintenance?
Regular maintenance ensures:
* Optimal energy efficiency (reducing operating costs)
* Improved indoor air quality (IAQ) by preventing contamination
* Extended equipment lifespan
* Compliance with health and safety regulations
* Basic checks (monthly): Filter inspection, fan operation, and visual checks.
* Comprehensive maintenance (quarterly/semi-annually): Coil cleaning, belt tension checks, motor lubrication.
* Professional inspection (annually): Full system diagnostics, ductwork inspection, and calibration.
* Reduced airflow or uneven temperature distribution
* Unusual noises (squealing, rattling) from fans/motors
* Increased energy bills (indicating inefficiency)
Foul odors or poor air quality
* Water leaks or excessive condensation
4. How often should AHU filters be replaced?
5. Can I clean and reuse AHU filters?
6. How do I maintain AHU coils?
* Standard filters: Every 3–6 months (depending on usage and environment).
* HEPA/High-efficiency filters: Every 6–12 months (or as per manufacturer guidelines).
* Dust-heavy environments (e.g., factories): More frequent replacement may be needed.
* Disposable filters: Must be replaced (cleaning damages them).
* Washable filters: Can be cleaned but must be thoroughly dried before reinstallation.
* Cleaning: Use a soft brush or coil cleaner to remove dirt/mold buildup.
* Inspection: Check for corrosion or refrigerant leaks (if applicable).
* Frequency: At least twice a year (more in dusty/humid environments).

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2641197". Items marked "verified" are certified.

Watch Video
Watch Video
Jiangsu Sujing Group Co., Ltd.
Jiangsu Sujing Group Co., Ltd.
Jiangsu Sujing Group Co., Ltd.
Jiangsu Sujing Group Co., Ltd.
Jiangsu Sujing Group Co., Ltd.
Jiangsu Sujing Group Co., Ltd.
Jiangsu Sujing Group Co., Ltd.
Jiangsu Sujing Group Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No 2 Wenxin Road, Industrial Park, Suzhou, Jiangsu, China
verified Plant Area
17182 square meters
verified Number of Employees
177
verified Registered Capital
160,000,000 RMB
Terms of Payment
LC, T/T
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 Piece
verified Supply Chain Partners
168

Our Production Capability & Technical Expertise

Main Products
Chillers, Dehumidifiers, Heat Pump, Air Conditioner, CO2 Heat Pump Units, Water Cooled Chiller, HVAC System, Air Handling Units, Heat Pump Units, Industrial Dehumidifier
verified Production Lines
1
verified Production Machines
Heat Exchanger Punching Equipment, Horizontal Tube Expander, Straight Pipe Cutting Machine, Pipe Bending Machine, Welding Robot, Plate Shearing Machine, CNC Punching Machine, Laser Cutting Machine, Air Conditioning Polyurethane Foam Equipment, CNC Lathe
verified QA/QC inspectors
4 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified R&D Engineers
11 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
1994-06-30
Export Year
2001-02-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
verified Overseas Agent/Branch
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE

FAQ

Why is regular AHU maintenance important?
Regular maintenance ensures optimal energy efficiency, improved indoor air quality by preventing contamination, extended equipment lifespan, and compliance with health and safety regulations.
How often should an AHU be serviced?
Basic checks should be performed monthly (filter inspection, fan operation). Comprehensive maintenance is required quarterly or semi-annually (coil cleaning, belt tension, motor lubrication). Professional inspection should occur annually.
What are the signs that an AHU needs maintenance?
Signs include reduced airflow, uneven temperature distribution, unusual noises (squealing, rattling), increased energy bills, foul odors, poor air quality, and water leaks or excessive condensation.
Can I clean and reuse AHU filters?
Disposable filters must be replaced as cleaning damages them. Washable filters can be cleaned but must be thoroughly dried before reinstallation.
How do I maintain AHU coils?
Clean coils using a soft brush or coil cleaner to remove dirt and mold. Inspect for corrosion or refrigerant leaks. Maintenance should be performed at least twice a year, or more frequently in dusty or humid environments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.